These functions operate on meta-data within the Multi API-DLL and help manage the underlying API-DLL instances. These functions do not directly program target devices. Use these functions to initialize the desired number of FPAs, selected all or one FPA(s), read FPA serial numbers, or clean-up resources used by Elprotronic’s DLLs.
Once the desired FPAs have been successfully opened, use Generic Functions to initialize the FPAs, and configure them for the target device(s) being programmed.
1. F OpenInstancesAndFPAs
General Description
Multi API-DLL scans USB ports or LAN for connected FPAs listed in the setup file, or input string. When an FPA listed in the setup file is found, the corresponding API-DLL is copied on disk if necessary, and loaded. F_Initialization should be called for each FPA after this function succeeds.
Syntax
INT_X F_OpenInstancesAndFPAs( char * FileName )
Input
char * FileName : path to setup file, or list of serial numbers.
Valid FPAs-setup.ini setup file lists FPAs and SN pairs.
FPA-1 20150003 FPA-2 20180134 --or-- FPA-1 20090123 FPA-2 * //any serial number (can only be done at last line)
Valid FPAsIPs.ini, setup file lists FPAs by IP address:
FPAETH-IP-1 192.168.0.101 FPAETH-IP-2 192.168.0.102 FPAETH-IP-3 192.168.0.103 FPAETH-IP-4 192.168.0.104
Invalid example:
FPA-1 * //this line will be read FPA-2 * //this line will be ignored
Valid list of serial numbers as a string:
"*# FPA-1 20090123 FPA-2 20090346"
translates to:
FPA-1 20090123 FPA-2 20090346
input string: "*# *" translates to:
FPA-1 *
In both cases, for the setup file and the input string, if a specified FPA is missing then it will not
affect subsequent entries. Therefore, a setup file with these contents:
FPA-1 20090123 FPA-2 20090346 FPA-3 20090222 FPA-4 20090245
and with FPA-3 missing (not connected, etc.) will initialize the Multi API-DLL to:
FPA-1 20090123 FPA-2 20090346 FPA-3 empty FPA-4 20090245
Output
INT_X : number of instances opened successfully
0 - failed
2. F_CloseInstances
General Description
All FPAs terminate communication with target devices and close target devices according to configuration settings (power setting, adapter line states, etc.). Finally, the USB/Ethernet connections to the FPAs are terminated and API-DLL instances are freed. The Multi API-DLL can now be used to open a new set of FPAs using the function F_OpenInstancesAndFPAs.
Syntax
INT_X F_CloseInstances ( void );
Input
none.
Output
INT_X : success or failed
TRUE (1) - success
FALSE (0) - failed
3. F_Set_FPA_index
General Description
Select desired FPA index to perform specific tasks (access specific API-DLL instance).
Syntax
INT_X F_Set_FPA_index ( BYTE fpa );
Input
BYTE fpa : desired FPA index, 1 to 64, or 0 for all
Output
INT_X : success or error
TRUE (1), used FPA index is valid
FPA_INVALID_NO (-2 or 0xFFFFFFFE) : FPA not opened with F OpenInstancesAndFPAs or index out of range
IMPORTANT
Other functions that try to access this FPA index will also return FPA_INVALID_NO if this function was not called with a proper parameter.
4. F_Get_FPA_index
General Description
Get current FPA index.
Syntax
BYTE F_Get_FPA_index( void );
Input
none.
Output
BYTE : current FPA index as set using F_Set_FPA_index
5. F_Check_FPA_index
General Description
Get current FPA index and check if index is valid. A valid index corresponds to an individual FPA that has been opened with F_OpenInstancesAndFPAs. If FPA index was set to 0 (all), then this function will only return 0, even if no FPAs are open. Does not indicate whether FPA index is enabled or disabled.
Syntax
INT_X F_Check_FPA_index ( void );
Input
none.
Output
INT_X : current fpa index if valid
current FPA index as entered using F_Set_FPA_index if selected FPA has been opened with F_OpenInstancesAndFPAs
FPA_INVALID_NO (-2 or 0xFFFFFFFE) : FPA not opened with F_OpenInstancesAndFPAs or index out of range
6. F_Enable_FPA_index
General Description
Enable desired FPA index to accept commands. An FPA index is enabled by default. A disabled FPA index will ignore commands when the FPA index is set to it, or 0 (all FPAs).
Syntax
void F_Enable_FPA_index ( BYTE fpa );
Input
BYTE fpa : desired FPA index, 1 to 64
Output
none.
7. F_Disable_FPA_index
General Description
Disable desired FPA index to ignore commands. An FPA index is enabled by default. A disabled FPA index will ignore commands when the FPA index is set to it, or 0 (all FPAs).
Syntax
void F_Disable_FPA_index ( BYTE fpa );
Input
BYTE fpa : desired FPA index, 1 to 64
Output
none.
8. F_LastStatus
General Description
Return value from the last function call issued to the specified FPA (API-DLL instance). This function is useful when multiple FPAs are being programmed using FPA index 0 (all), but the return value was not the same for all FPAs (i.e. 4 FPAs succeeded, 1 FPA failed). When the return value is not the same for all FPAs then, then the actual return value from the Multi API-DLL will be FPA_UNMATCHED_RESULTS. To find out per FPA return values, select each FPA index individually using F_Set_FPA_index, and call F_LastStatus for each index.
Syntax
INT_X F_LastStatus ( BYTE fpa );
Input
BYTE fpa : desired FPA index, 1 to 64.
Output
INT_X : Last return value from the selected FPA (API-DLL instance).
INT_X type return value from last function call on selected FPA
FPA_INVALID_NO (-2 or 0xFFFFFFFE) : FPA not opened with F_OpenInstancesAndFPAs or index out of range
9. F_Multi_DLLTypeVer
General Description
Get Multi API-DLL software version number.
Syntax
INT_X F_Multi_DLLTypeVer( void );
Input
none.
Output
INT X : (DLL_ID) | (Version)
// return Type + Version // Type 0x6000 - Multi-FPA FlashPro430 // 0x7000 - Multi-FPA GangPro430 // 0x8000 - Multi-FPA FlashPro-CC // 0x9000 - Multi-FPA GangPro-CC // 0xC000 - Multi-FPA FlashPro2000 // 0xD000 - Multi-FPA GangPro2000 // 0x10000 - Multi-FPA FlashPro-ARM // 0x11000 - Multi-FPA GangPro-ARM // 0x17000 - Multi-FPA FlashPro-M // 0x18000 - Multi-FPA GangPro-M // Version = 0x0FFF & version
FPA_INVALID_NO (-2 or 0xFFFFFFFE) : FPA not opened with F_OpenInstancesAndFPAs or index out of range
10. F_Get_FPA_SN
General Description
Get serial number (SN) of FPA assigned to specified index.
Syntax
INT_X F_Get_FPA_SN ( BYTE fpa );
Input
BYTE fpa : desired FPA index, 1 to 64
Output
INT_X : serial number
SN of selected FPA
FPA_INVALID_NO (-2 or 0xFFFFFFFE) : FPA not opened with F_OpenInstancesAndFPAs or index out of range
11. F_Get_FPA_Label
General Description
Get detailed information of FPA assigned to specified index.
Syntax
INT_X F_Get_FPA_Label ( BYTE fpa, BYTE *label );
Input
BYTE fpa : desired FPA index, 1 to 64.
BYTE *label : pointer to instance of FPA_LABEL and bytes array, i.e.
FPA_LABEL inst; F_Get_FPA_Label(i, inst.bytes); //get label for FPA-i
#define ADAPTER_HARDWARE_PN_SIZE 16 #define ADAPTER_DESCRIPTION_SIZE 32 #define FPA_LABEL_SIZE ((ADAPTER_HARDWARE_PN_SIZE + ADAPTER_DESCRIPTION_SIZE)*sizeof(char) + 12*sizeof(BYTE) + sizeof(long)) union FPA_LABEL { BYTE bytes[ FPA_LABEL_SIZE ]; struct { long SN; BYTE hardware_ID; BYTE hardware_SubID; BYTE full_access; BYTE Interface_Type; BYTE Valid_access_key; BYTE spare3; BYTE spare4; BYTE spare5; BYTE spare6; BYTE spare7; BYTE spare8; BYTE spare9; char adapter_hardware_PN[ ADAPTER_HARDWARE_PN_SIZE ]; char adapter_description[ ADAPTER_DESCRIPTION_SIZE ]; }x; };
Output
INT_X : serial number, hardware ID, meta-data
updated FPA_LABEL structure pointed to by label input parameter
FPA_INVALID_NO (-2 or 0xFFFFFFFE) : FPA not opened with F_OpenInstancesAndFPAs or index out of range
Example of printing FPA_LABEL:
std::stringstream msg; msg << "INIT: " << (i) << ": Get_FPA_Label, SN=" << inst.x.SN << "\r\n"; msg << "INIT: HW ID=" << (int)inst.x.hardware_ID << ", HW sub-ID=" << (int)inst.x.hardware_SubID << "\r\n"; msg << "INIT: Full Access=" << (int)inst.x.full_access << ", Interface Type=" << (int)inst.x.Interface_Type << "\r\n"; msg << "INIT: Access Key=" << (int)inst.x.Valid_access_key << "\r\n"; msg << "INIT: HW PN=" << inst.x.adapter_hardware_PN << "\r\n"; msg << "INIT: Adapter Desc=" << inst.x.adapter_description;
12. F_Get_FPA_List
General Description
This function will print the metadata about all avaialble FPAs that are connected to the computer, up to a maximum of 64 adapters.
Syntax
INT_X MSPPRG_API F_Get_FPA_List( ALL_FPA_LIST * FPA_List );
Input
ALL_FPA_LIST *FPA_List: pointer to array of ALL_FPA_LIST structs, i.e.
#define MAX_ID_DESC 15 #define MAX_ACCESS_DESC 32 typedef struct { UINT32 active; UINT32 SN; UINT32 CommType; UINT32 HW_ID; UINT32 HW_rev; char text[MAX_ID_DESC+1]; char access_text[MAX_ACCESS_DESC+1]; } ALL_FPA_LIST; //i.e.: ALL_FPA_LIST FPA_List[MAX_USB_DEV_NUMBER]; //F_Get_FPA_List(FPA_List); INT_X MSPPRG_API F_Get_FPA_List( ALL_FPA_LIST * FPA_List ); // FPA_List -> size MAX_USB_DEV_NUMBER
Output
INT_X : number of active adapters
13. F_GetProgressBar
General Description
Get internal progress counter value for operations done inside Encapsulated Functions . When used in conjunction with F_GetLastOpCode it allows the user application to keep track of progress in the same way that the FlashPro-ARM/GangPro-ARM GUI does.
Will return value between 0 and 100 for current sub-operation being performed inside encapsulated function. Depending on the complexity of the encapsulated function, the number of sub-operations will vary. Use F GetLastOpCode to get currently running sub-operation opcode. When transitioning from one sub-operation that reached a progress value of 100, to another sub-operation, the progress value will restart at 0. This will repeat until the last sub-operation upon which the progress value will remain at 100. A new invocation of an encapsulated function will restart the progress value at 0.
This function is thread-safe, therefore it can be called while the Multi API-DLL is busy, for example running F_AutoProgram. Intended usage is to call an encapsulated function with one thread, and repeatedly call this function and F_GetLastOpCode with another thread. When simultaneously programming using multiple FPAs (fpa index set to 0 (ALL FPAs), the thread monitoring progress can iterate different input parameters (fpa=1, fpa=2, fpa=3, etc.) to monitor the progress of each FPA individually. This function cannot be called with parameter 0 (ALL FPAs).
Syntax
INT_X MSPPRG_API F_GetProgressBar( BYTE fpa );
Input
BYTE fpa : desired FPA index, 1 to 64.
Output
INT_X : progress indicator
value between 0 and 100
FPA_INVALID_NO (-2 or 0xFFFFFFFE) : FPA not opened with F_OpenInstancesAndFPAs or index out of range
Example
Refer to GetLastOpCode.
14. F_GetLastOpCode
General Description
Read internal opcode value for sub-operations done inside Encapsulated Functions. When used in conjunction with F_GetProgressBar it allows the user application to keep track of progress in the same way that the FlashPro-ARM/GangPro-ARM GUI does.
Will return opcode for current sub-operation being performed inside encapsulated function. Depending on the complexity of the encapsulated function, the number of sub-operations will vary. Use F_GetProgressBar to get progress value between 0 and 100, of currently running sub-operation. When transitioning from one sub-operation that reached a progress value of 100, to another sub-operation, the progress value will restart at 0 and the opcode will be set to the new sub-operation, currently being run. This will repeat until the last sub-operation upon which the opcode will not change. A new invocation of an encapsulated function will reset the opcode to the first sub-operation of the new encapsulated function.
This function is thread-safe, therefore it can be called while the Multi API-DLL is busy, for example running F_AutoProgram. Intended usage is to call an encapsulated function with one thread, and repeatedly call this function and F_GetProgressBar with another thread. When simultaneously programming using multiple FPAs (fpa index set to 0 (ALL FPAs), the thread monitoring progress can iterate different input parameters (fpa=1, fpa=2, fpa=3, etc.) to monitor the progress of each FPA individually. This function cannot be called with parameter 0 (ALL FPAs).
Syntax
INT_X MSPPRG_API F_GetLastOpCode( BYTE fpa );
Input
BYTE fpa : desired FPA index, 1 to 64.
Output
INT_X : opcode of currently running sub-operation
PROG_OPCODE_VERIFY_ACCESS (1) : FPA is attempting to perform action described in F_Verify_Access to MCU.
PROG_OPCODE_FLASH_ERASE (2) : FPA is attempting to perform action described in F_Memory_Erase.
PROG_OPCODE_FLASH_BLANK_CHECK (3) : FPA is attempting to perform action described in F_Memory_Blank_Check.
PROG_OPCODE_FLASH_SELECTED_BLANK_CHECK (4) : FPA is attempting to perform action described in F_Memory_Blank_Check when a subset of the memory space is selected in configuration settings.
PROG_OPCODE_FLASH_WRITE (5) : FPA is attempting to perform action described in F_Memory_Write.
PROG_OPCODE_FLASH_VERIFY (6) : FPA is attempting to perform action described in F_Memory_Verify.
PROG_OPCODE_FLASH_READ (7) : FPA is attempting to perform action described in F_Memory_Read.
PROG_OPCODE_LOCK_MCU (8) : FPA is attempting to perform action described in F_Lock_MCU.
PROG_OPCODE_UNLOCK_MCU (9) : FPA is attempting to perform action described in F_Clear_Locked_Device.
PROG_OPCODE_START_APP (10) : FPA is attempting to run application programmed onto target device (if enabled to be ran after F_AutoProgram in configuration settings).
FPA INVALID NO (-2 or 0xFFFFFFFE) : FPA not opened with F_OpenInstancesAndFPAs or index out of range
Example
void UpdateProgress(BYTE fpa, INT_X &progValue, INT_X &lastOpCode, CString &opCodeUpdate) { if(fpa == 0) { //invalid index return; } progValue = F_GetProgressBar(fpa); lastOpCode = F_GetLastOpCode(fpa); opCodeUpdate = "Unknown"; switch(lastOpCode) { case PROG_OPCODE_VERIFY_ACCESS: opCodeUpdate = "Verify Access To MCU"; break; case PROG_OPCODE_FLASH_ERASE: opCodeUpdate = "Flash Erase"; break; case PROG_OPCODE_FLASH_BLANK_CHECK: opCodeUpdate = "Flash Blank Check"; break; case PROG_OPCODE_FLASH_SELECTED_BLANK_CHECK: opCodeUpdate = "Selected Memory Blank Check"; break; case PROG_OPCODE_FLASH_WRITE: opCodeUpdate = "Flash Write"; break; case PROG_OPCODE_FLASH_VERIFY: opCodeUpdate = "Flash Verify"; break; case PROG_OPCODE_FLASH_READ: opCodeUpdate = "Flash Read"; break; case PROG_OPCODE_LOCK_MCU: opCodeUpdate = "Lock MCU"; break; case PROG_OPCODE_UNLOCK_MCU: opCodeUpdate = "Unlock MCU"; break; case PROG_OPCODE_START_APP: opCodeUpdate = "Start Application"; break; } }
15. F_Cancel_Action
General Description
Function that will attempt to cancel any running Encapsulated Functions , like the GUI Cancel button. This function is thread-safe. One thread can call F_AutoProgram (for example) and another thread can call F_CancelAction to stop the first. A reinitialization is recommended using F_OpenInstancesAndFPAs after calling this function.
Syntax
INT_X MSPPRG_API F_CancelAction( BYTE fpa );
Input
BYTE fpa : desired FPA index, 1 to 64.
Output
INT_X : success or failed
TRUE (1) - success
FALSE (0) - failed
16. F_Trace_File
General Description
Set custom FileName for trace (used with Trace_ON). Set append flag true to keep previous contents.
Syntax
INT_X F_Trace_File( char *FileName, bool append = false );
Input
char *FileName : path to new trace file.
bool append : append to file if it already exists.
Output
INT_X : success or failed in opening file
TRUE (1) - success
FALSE (0) - failed
17. F_Trace_Comment
General Description
Append a custom comment to current trace file.
Syntax
void MSPPRG_API F_Trace_Comment(char *comment);
Input
char *comment : comment to be added to trace file at current location in the trace.
Output
none.
18. F_Trace_ON
General Description
Activate tracing for subsequent calls to the Multi API-DLL. Log is saved in DLLtrace.txt located in the Multi API-DLL directory, or custom file if F_Trace_File function was called. When activated, records all API-DLL function calls from the application software invoked via the Multi API-DLL. The trace file is overwritten for each new session, unless the F_Trace_File append flag is true.
Syntax
void F_Trace_ON( void );
Input
none.
Output
none.
19. F_Trace_OFF
General Description
Disable tracing.
Syntax
void F_Trace_OFF( void );
Input
none.
Output
none.